  2. 實驗室供水給電方面的改造工作要知道

    來源:http://www.bristolbakestress.com/ 發布時間:2022-05-07
    鑒于手術室建設的復雜性,涉及多個領域,須滿足一些設計和施工的技術要求。下面來講講手術室設備層的相關建設要點吧!
    In view of the complexity of the construction of the operating room, which involves many fields, some technical requirements for design and construction must be met. Now let's talk about the key points of the construction of the equipment floor in the operating room!
    手術室建設時,設備層的空間除了要足夠安裝各種大型設備,還需要預留一定的位置和通道供維護管理人員對凈化空調系統進行維護和維修工作,如更換過濾器,檢查風機、電機、加濕器、自控系統及各種閥門等。
    During the construction of the operating room, the space on the equipment floor should be enough to install all kinds of large equipment, and a certain position and channel should be reserved for maintenance and management personnel to maintain and repair the purification air conditioning system, such as replacing filters, checking fans, motors, humidifiers, automatic control systems and various valves.
    部分項目的手術部凈化設備層層高非常低,建筑層高通常只有2.1m,梁底高度只有1.6m,設備安裝非常擁擠、困難,導致工程安裝質量下降。
    The floor height of purification equipment in the operating department of some projects is very low. The building floor height is usually only 2.1m, and the beam bottom height is only 1.6m. The equipment installation is very crowded and difficult, which leads to the decline of engineering installation quality.
    工程完成后由于沒有足夠的檢修空間,系統設備無法得到恰當的維護保養,很快就出現各種故障。所以,建議在大樓設計階段就需要重視設備層的空間要求,建議設備層層高大于2.8m,梁底凈高不小于2.2m。
    After the project is completed, because there is not enough maintenance space, the system equipment cannot be properly maintained, and various failures will occur soon. Therefore, it is suggested that attention should be paid to the space requirements of the equipment floor at the building design stage. It is suggested that the equipment floor height should be greater than 2.8m and the clear height of the beam bottom should not be less than 2.2m.
    手術室建設
    需注意的事項:
    Notes:
    設備層的作為手術室的通風系統的主體,與手術室起著連通的作用,因此,設備層的留洞顯得非常重要。
    As the main body of the ventilation system of the operating room, the equipment layer plays a role in connecting with the operating room. Therefore, it is very important to reserve holes in the equipment layer.
    要定準設備層留洞,需要先定準工藝布局,然后針對布局做好專門的設計方案。
    To determine the reserved holes on the equipment floor, the process layout needs to be determined first, and then a special design scheme should be made for the layout.
    設備層洞口預留要考慮余量,不然加固后難以擴大。
    Allowance shall be considered for the reserved opening of the equipment layer, otherwise it is difficult to expand after reinforcement.
    設備層地面須做防水處理,所以預留洞口需做防水臺。
    The ground of the equipment layer must be waterproof, so the reserved holes need to be waterproof platform.
    設備層須合理配置凈化機組冷卻水排放的地漏,不建議機組至地漏冷凝水管道過長。
    The floor drain for cooling water discharge of the purification unit must be reasonably configured on the equipment floor. It is not recommended that the condensate pipe from the unit to the floor drain be too long.
    手術室設備層的相關建設要點就是如上所講解的這樣了,你對此有什么相關事項就來我們網站http://www.bristolbakestress.com進行咨詢吧!